Cristec BAT-MON-3.5-3 – Touch screen battery monitor c/w 1 x 300A shunt

£351.00 ex. VAT

Cristec BAT-MON-3.5-3 touch-screen battery monitor supplied with one 300A shunt. Contact F&C Marine for battery-bank matching, installation and support.

SKU: BAT-MON-3.5-3 Categories: , Brand:

Description

Cristec BAT-MON-3.5-3 battery monitor

Cristec BAT-MON-3.5-3 is the touch-screen battery monitor listed with one 300A shunt. It is intended to monitor battery or DC-source current flow as part of a marine electrical installation. A battery monitor is only as useful as the installation and configuration behind it, so the battery bank, shunt position, cable arrangement, charging sources and loads should all be identified before fitting or replacing the monitor.

Cristec BAT-MON-3.5-3

What the monitor needs to measure

Before installation, decide which battery bank or DC source needs to be monitored and identify every charge and load path associated with it. The shunt must be incorporated into the system in accordance with the current Cristec documentation so that the current being measured is representative of the bank being monitored. On an existing vessel, undocumented additions such as chargers, solar controllers or auxiliary loads can bypass a monitoring arrangement and produce misleading readings, so the present wiring should be traced before commissioning.

Battery-bank information and setup

Record the nominal battery voltage, chemistry, capacity and number of batteries in the bank. A monitor may need configuration that reflects the actual battery installation, so settings inherited from an older bank should not simply be reused after a battery change. If lithium batteries are fitted, review any BMS information and other monitoring already present. If lead-acid batteries are used, battery condition and capacity can influence what the displayed figures mean in practice. The monitor should support maintenance decisions, not replace basic voltage and battery-condition checks.

Shunt, cabling and protection

High-current battery circuits require careful installation. The supplied 300A shunt and associated conductors should be installed in the arrangement specified by Cristec, with suitable cable sizing, protection, mechanical support and access for inspection. Keep sensing and communication wiring protected from chafe, water and accidental damage. Existing battery cables, lugs, busbars and isolators should be checked for corrosion, overheating or loose connections when the monitor is added, because poor high-current connections can cause voltage drop and misleading symptoms elsewhere in the system.

Display location and service access

Choose a display position that is convenient to read without exposing the unit to an unsuitable environment. Plan the cable route before cutting panels or modifying joinery, and leave enough access for future service. If replacing another monitor, confirm that the existing aperture, wiring and shunt arrangement are compatible rather than assuming the new unit is a direct electrical substitute. Label the installation so future engineers can identify the monitored bank, shunt and any communication connections quickly.

Commissioning and checking readings

After installation, verify polarity, supply and configuration before relying on the displayed values. Observe the monitor with known loads switched on and with charging sources operating so that current direction and response can be checked. Compare voltage with an independent meter where practical. If readings appear implausible, inspect the shunt connections, bypass paths, configuration and battery wiring before assuming the display is faulty. Record the final settings and battery-bank details for future maintenance or battery replacement.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. The current Cristec instructions should be the final reference for shunt installation, wiring, configuration and environmental requirements. F&C Marine also provides a Marine Electronics Knowledge Base covering practical marine electrical and electronics installation topics.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec BAT-MON-3.5-3

Send F&C Marine the vessel type, battery-bank voltage, chemistry and capacity, existing monitor information, main charging sources and loads, photographs of the battery and distribution wiring and the proposed display location. If replacing a faulty monitor, include the symptoms and any measurements already taken. We can then help confirm compatibility, likely installation requirements and current availability before quotation.

Reviews

There are no reviews yet.