Cristec IT-3600-A – 3600W Automatic transformer – 115/230VAC

£538.00 ex. VAT

Cristec IT-3600-A 3600W automatic 115/230VAC marine isolation transformer. Contact F&C Marine for system matching and installation support.

SKU: IT-3600-A Categories: , Brand:

Description

Cristec IT-3600-A marine isolation transformer

Cristec IT-3600-A is the 3600W automatic 115/230VAC transformer configuration listed in the Cristec range. A shore-power transformer forms part of a mains-voltage vessel installation, so correct selection depends on shore supply, onboard voltage, load, protection, earthing, cable sizing, mounting and ventilation. Installation and commissioning should be carried out by a competent marine electrician using the current Cristec instructions and applicable electrical standards.

Cristec IT-3600-A

Automatic 115/230VAC configuration

This model is identified as the automatic 3600W version for 115/230VAC arrangements. Before ordering, establish the shore supply expected at the vessel and the AC voltage required by the onboard distribution system. The automatic operating arrangement and permitted input/output conditions should be confirmed from current manufacturer documentation before installation. A transformer should not be selected solely on physical size or nominal wattage because protection, cable ratings and connected loads all form part of the system.

Load assessment and shore-power planning

List the major AC loads that may operate simultaneously and compare expected demand with the transformer rating and vessel distribution design. Consider chargers, heaters, galley equipment, pumps, electronics and other loads rather than relying only on a breaker label. If a previous transformer has overheated or tripped, investigate the actual load and supply voltage before replacing it. A new unit will not correct an overloaded circuit, weak shore connection or damaged cable.

Earthing and electrical safety

Isolation transformers interact with the vessel’s protective-earthing arrangement, so earthing and neutral treatment must follow the applicable marine electrical rules and the Cristec installation instructions. This is safety-critical work and should not be improvised. Existing shore inlets, RCDs, breakers, changeover switches and protective conductors should be identified before modification. Work should be isolated and verified safe before mains conductors are disturbed.

Mounting, ventilation and cable routes

Transformers can be heavy and may generate heat in operation. The mounting structure, orientation, environmental protection and ventilation requirements need to be checked before installation. Keep the equipment accessible for service and protect cable entries from strain and mechanical damage. On a refit, inspect existing AC cables and terminals for overheating, corrosion or previous alterations rather than assuming they are suitable for the replacement.

Commissioning the AC system

Commissioning should verify the shore input, automatic operating behaviour, output voltage, protective devices and operation of representative vessel loads. Any tests required for protective earth, insulation or RCD operation should be completed using appropriate procedures and equipment. Observe the system under realistic load and investigate abnormal heating, voltage drop or nuisance tripping before handover. Record the model, configuration and protective-device details for future electrical inspections.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. The current Cristec manual is the final reference for input/output configuration, protection, earthing, mounting and commissioning. F&C Marine also provides a Marine Electronics Knowledge Base covering vessel electrical and electronics topics.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec IT-3600-A

Send F&C Marine the vessel type, shore inlet and supply details, required onboard AC voltage, existing transformer model, main AC loads, breaker/RCD information, available mounting space and photographs of the installation. We can then help confirm whether the 3600W automatic 115/230VAC version is the right model and identify the information needed for safe professional installation.

Reviews