Cristec KERS12-115/3600 – Kersine 3600VA 12VDC Inverter

£1,728.00 ex. VAT

Cristec KERS12-115/3600 Kersine 3600VA marine inverter for 12VDC systems. Contact F&C Marine for load, battery and installation matching.

SKU: KERS12-115/3600 Categories: , Brand:

Description

Cristec KERS12-115/3600 Kersine marine inverter

Cristec KERS12-115/3600 is the Kersine 3600VA inverter configuration listed for a 12VDC battery system. Marine inverter selection needs to consider more than the nominal VA rating: battery-bank capacity, DC current, cable length, protection, AC loads, earthing, transfer arrangements, mounting and ventilation all need to suit the vessel. Because the unit produces mains voltage, AC installation and commissioning should be carried out by a competent person using current Cristec instructions.

Cristec KERS12-115/3600

Matching a 3600VA inverter to the load

List the AC equipment expected to operate from the inverter and consider normal running demand as well as starting or surge loads. Motors, compressors, pumps and some power supplies can draw substantially more current at start-up than their normal rating suggests. Avoid sizing the inverter purely from the sum of label wattages without considering how the vessel will actually use the equipment. If an older inverter has been tripping, determine whether the cause is overload, low battery voltage or a wiring fault before replacing it.

12V battery-bank requirements

A 3600VA inverter on a 12V system can demand substantial DC current, so battery capacity, chemistry, state of charge and charging-system capability are critical. Check shore chargers, alternators, solar controllers and any battery-management system as part of the design. A larger inverter connected to an inadequate bank may suffer low-voltage shutdowns or poor battery endurance. Lithium installations must remain within BMS current limits, while lead-acid systems should be assessed for voltage sag under heavy load.

DC cabling, fusing and isolation

The DC side requires appropriately sized conductors, short practical cable routes and suitable overcurrent protection and isolation. High resistance in a terminal or undersized cable can cause large voltage drops at inverter load. Inspect lugs, busbars, fuses and isolators for heat damage or corrosion and support heavy battery cables so they do not strain equipment terminals. Follow current manufacturer instructions for cable and protective-device requirements rather than copying an older installation automatically.

AC integration and safety

The inverter output is mains voltage and must be integrated with the vessel AC system using appropriate protection, isolation and changeover arrangements. Neutral and protective-earth treatment must follow applicable marine electrical requirements and Cristec instructions. Do not connect an inverter into an existing shore-power circuit without understanding how sources are separated. Work on the AC distribution should be isolated and verified safe, and installation should be completed by a competent marine electrician.

Mounting, cooling and commissioning

Install the inverter in a dry, protected location with ventilation and clearances specified by Cristec. Keep it accessible for fuses, terminals and service. Commissioning should verify battery voltage at idle and under load, representative AC loads, protective devices and any alarms or shutdowns. Check for abnormal heating and excessive DC voltage drop. Record the model, battery-bank details, cable protection and connected AC circuits so future servicing has a clear baseline.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. Use current Kersine documentation as the final reference for electrical ratings, cabling, protection, earthing, mounting and operation. F&C Marine also provides a Marine Electronics Knowledge Base for related vessel electrical guidance.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec KERS12-115/3600

Send F&C Marine the vessel type, battery voltage, chemistry and capacity, existing inverter model, main AC loads, cable length, charging-system details and photographs of the installation. If this is a fault replacement, include alarm or shutdown symptoms and voltage measurements. We can then help confirm the correct Kersine configuration and installation requirements before quotation.