Cristec KERS12-230/3600-REL – Kersine 3600VA 12VDC Inverter

£1,732.00 ex. VAT

Cristec KERS12-230/3600-REL Kersine 3600VA marine inverter for 12VDC systems. Contact F&C Marine for exact variant, load and installation matching.

SKU: KERS12-230/3600-REL Categories: , Brand:

Description

Cristec KERS12-230/3600-REL Kersine marine inverter

Cristec KERS12-230/3600-REL is the Kersine 3600VA inverter configuration listed for a 12VDC battery system. The REL suffix identifies this exact catalogue variant and should be retained when ordering or replacing equipment. Marine inverter selection needs to consider battery-bank capacity, DC current, cable length, protection, AC loads, earthing, transfer arrangements, mounting and ventilation. Because the unit produces mains voltage, AC installation and commissioning should be carried out by a competent person using current Cristec documentation.

Cristec KERS12-230/3600-REL

Matching a 3600VA inverter to the load

List the AC equipment expected to operate from the inverter and consider normal running demand as well as starting or surge loads. Motors, compressors, pumps and some power supplies can draw substantially more current at start-up than their normal rating suggests. Avoid sizing the inverter purely from the sum of label wattages without considering how the vessel will actually use the equipment. If an older inverter has been tripping, determine whether the cause is overload, low battery voltage or a wiring fault before replacing it.

12V battery-bank requirements

A 3600VA inverter on a 12V system can demand substantial DC current, so battery capacity, chemistry, state of charge and charging-system capability are critical. Check shore chargers, alternators, solar controllers and any battery-management system. An inadequate bank may produce low-voltage shutdowns or poor endurance. Lithium installations must remain within BMS current limits, while lead-acid systems should be checked for condition and voltage sag under heavy load.

DC cabling, fusing and isolation

The DC side requires appropriately sized conductors, short practical cable routes and suitable overcurrent protection and isolation. High resistance in a terminal or undersized cable can cause large voltage drops at inverter load. Inspect lugs, busbars, fuses and isolators for heat damage or corrosion and support heavy battery cables so they do not strain equipment terminals. Follow current manufacturer instructions for cable and protective-device requirements.

AC integration and safety

The inverter output is mains voltage and must be integrated with the vessel AC system using appropriate protection, isolation and source-changeover arrangements. Neutral and protective-earth treatment must follow applicable marine electrical requirements and Cristec instructions. The exact REL variant should be checked against current manufacturer documentation before assuming any additional function from the suffix. Work on the AC distribution should be isolated, verified safe and completed by a competent marine electrician.

Mounting, cooling and commissioning

Install the inverter in a dry, protected location with ventilation and clearances specified by Cristec. Keep it accessible for fuses, terminals and service. Commissioning should verify battery voltage at idle and under load, representative AC loads, protective devices and any alarms or shutdowns. Check for abnormal heating and excessive DC voltage drop. Record the exact REL model, battery-bank details, cable protection and connected AC circuits for future servicing.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. Use current Kersine documentation as the final reference for electrical ratings, variant functions, cabling, protection, earthing, mounting and operation. F&C Marine also provides a Marine Electronics Knowledge Base for related vessel electrical guidance.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec KERS12-230/3600-REL

Send F&C Marine the vessel type, battery voltage, chemistry and capacity, existing inverter model, main AC loads, cable length, charging-system details and photographs of the installation. If replacing another Kersine unit, include the complete model suffix. We can then help confirm the correct REL configuration and installation requirements before quotation.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.