Cristec RCB-ADJ-120PL adjustable battery coupler relay
Cristec RCB-ADJ-120PL is listed as an adjustable 30A to 120A battery coupler relay. It is intended for battery-bank coupling within a marine DC system, but the correct setting and installation depend on the battery banks, charging sources, conductor sizes, protection and operating requirement. F&C Marine can help review the complete system before this adjustable version is selected.

Why the adjustable current range matters
The listed 30A to 120A range gives flexibility, but it should not be treated as an invitation to select a setting without considering the rest of the installation. Determine the expected current between the banks, the capabilities of the charging source, the battery technologies and the cable/protection limits. The current Cristec instructions should be used to establish how the adjustable function is intended to be configured and how that setting interacts with the connected system.
Battery-bank and charging compatibility
Identify the source and secondary banks by nominal voltage, chemistry, capacity and vessel duty. Review alternators, shore chargers, solar controllers and other charge sources connected to either bank. Lithium conversions can materially change charge current and control requirements compared with older lead-acid systems. The coupler should therefore be considered as part of the whole charging strategy rather than as a standalone relay.
Cabling, fusing and isolation
Use conductors sized for the maximum current that the configured system can carry, not merely a normal average. Cable length and acceptable voltage drop also matter. Protect positive conductors appropriately and inspect existing fuses, isolators, lugs and busbars for corrosion or heat damage. Heavy cables should be supported so they do not strain terminals. If an older relay is being replaced, label and photograph every connection before removal so the original arrangement can be checked rather than guessed.
Mounting and configuration
Mount the relay in a dry, protected position that meets the current Cristec requirements and remains accessible for adjustment and service. Any control, sensing or communication connections should be identified before installation. After setting the unit, document the chosen configuration and the reason for it. This is particularly important on commercial vessels where future engineers may otherwise have no way to know whether a previous adjustment was deliberate.
Commissioning and diagnostics
Before energising, verify polarity, protection and both bank voltages. Test the system with relevant charging sources and loads and confirm that coupling behaviour is consistent with the manufacturer procedure. Measure voltage and inspect high-current joints for excessive drop or heating. If behaviour is unexpected, check battery condition, charger voltage, cable resistance, fuses and the configured setting before assuming the relay is faulty. Record the final setting and connection layout.
Documentation and related guidance
For current manufacturer information see Cristec marine electrical products. Use the current Cristec instructions as the final reference for the adjustable range, thresholds, wiring, protection and installation. F&C Marine also provides a Marine Electronics Knowledge Base with marine electrical guidance.
Official manuals, datasheets and brochures
Related products
- Cristec RCB-80A – 80A/80A smart battery coupler relay
- Cristec RCB-50A – 50A/50A smart battery coupler relay
Related technical resources
Before ordering Cristec RCB-ADJ-120PL
Send F&C Marine the vessel type, system voltage, battery-bank capacities and chemistries, alternator and charger details, expected inter-bank current, cable sizes and photographs of the current installation. If replacing another coupler, include its model and any known settings. We can then help confirm whether the adjustable 30A-120A model is appropriate and identify installation requirements.