Description
Cristec RCE/100-2E-3IG battery distribution unit
Cristec RCE/100-2E-3IG is listed as a 100A unit with two inputs and three outputs. In a marine DC system, a battery distribution or charge-splitting device should be selected around the sources, battery banks, cable sizes and protection rather than current rating alone. F&C Marine can help confirm whether this exact input/output arrangement suits the vessel before equipment is ordered.

Understanding the two-input, three-output arrangement
Before installation, identify every charging source and battery bank that will connect to the RCE unit. Two inputs and three outputs can be useful in a multi-bank system, but the actual wiring should follow the current Cristec documentation and the vessel’s electrical design. Record whether the sources are alternators, battery chargers or other DC supplies and identify the nominal voltage and capacity of each destination bank. Do not assume that similar-looking terminals on an existing splitter have the same function.
Current rating and system load
The listed 100A rating must be considered with the charging sources and expected operating conditions. Check the maximum current available from each source and the requirements of the battery banks. Battery chemistry and charging equipment can change the current profile significantly, particularly after a lithium conversion or alternator upgrade. If the existing installation has experienced overheating, low charge current or unequal battery charging, inspect the cables and connections before deciding the splitter itself is at fault.
Cabling, fusing and connection quality
High-current DC distribution requires correctly sized conductors and appropriate protection. Cable size should account for maximum current, route length and acceptable voltage drop. Inspect lugs, busbars, isolators and fuses for corrosion, loose connections or heat damage. Keep cables supported so their weight does not load the terminals and protect exposed positive connections from accidental short circuit. When replacing an older unit, label and photograph every cable before disconnection so the original system can be understood and checked.
Battery banks and charging sources
Different battery banks may serve engine starting, domestic, communications or other vessel services. The charging arrangement should ensure each bank is supplied in a manner compatible with its chemistry and intended duty. If batteries of different technologies are present, or if multiple chargers and alternators are connected, review the complete charging strategy rather than treating the RCE as an isolated component. Manufacturer limits and battery recommendations should be used when deciding how the system is configured.
Commissioning and fault finding
Before energising, verify polarity, cable protection and terminal identification. After commissioning, measure source and battery voltages under charging conditions and check for excessive voltage drop or heating at connections. Confirm that the intended banks receive charging current and that other vessel systems operate normally. If one bank charges poorly, test battery condition, cabling and connection resistance before condemning the distribution device. Record the final cable destinations and protective-device ratings for future service.
Documentation and related guidance
For current manufacturer information see Cristec marine electrical products. Use the current Cristec instructions as the final reference for terminal functions, ratings, wiring and installation. F&C Marine’s Marine Electronics Knowledge Base also contains practical marine electrical guidance.
Official manuals, datasheets and brochures
Related products
- Cristec RCE/150-1E-2IG – 150Amp – 1 Input 2 Outputs
- Cristec RCE80-1EM6-2SM6-PL – 80 Amp – 1 Input – 2 Outputs, M6 terminal
- Cristec RCE120-1EM6-2SM6-PL – 120 Amp – 1 Input – 2 Outputs, M6 terminal
Related technical resources
Before ordering Cristec RCE/100-2E-3IG
Send F&C Marine the vessel type, system voltage, charging-source details, battery-bank voltage and chemistry, number of banks, approximate cable lengths and photographs of the existing distribution arrangement. If this is a replacement, include the old unit’s model and symptoms. We can then help check whether the 100A two-input, three-output configuration is suitable and identify likely installation requirements.