Cristec RCE160-2EM6-3SM6-PL – 160 Amp – 2 Input – 3 Outputs, M6 terminal

£168.00 ex. VAT

Cristec RCE160-2EM6-3SM6-PL 160A battery distribution unit with two inputs, three outputs and M6 terminals. Contact F&C Marine for system matching.

SKU: RCE160-2EM6-3SM6-PL Categories: , Brand:

Description

Cristec RCE160-2EM6-3SM6-PL battery distribution unit

Cristec RCE160-2EM6-3SM6-PL is listed as a 160A unit with two inputs, three outputs and M6 terminals. A multi-input battery distribution system should be planned around all charging sources and destination banks rather than the current rating alone. The exact model reference matters because the number of inputs, outputs and terminal sizes differ across the Cristec RCE range.

Cristec RCE160-2EM6-3SM6-PL

Two charging inputs and three battery outputs

Identify both charging sources and all three destination battery banks before installation. Record whether the inputs are alternators, shore chargers or other DC sources, together with system voltage and maximum current. The battery banks should also be identified by chemistry, capacity and duty. Follow the current Cristec terminal information rather than assuming an existing unit is wired in the same order, particularly on a vessel that may have been modified since the original installation.

Current rating and cable selection

The listed 160A rating needs to be considered with the combined charging arrangement and the current that may flow through each connection. Cable size depends on current, route length, conductor rating and acceptable voltage drop. Inspect existing cables and lugs for corrosion, overheating or undersizing before reuse. Heavy conductors should be mechanically supported and positive terminals protected from accidental contact. M6 terminal hardware should be matched with correctly sized lugs and secure connections.

Battery-bank and charger compatibility

Multiple battery banks may serve engine-starting, domestic, communications or auxiliary duties. The charging strategy should still be suitable for the battery technologies installed. If lithium and lead-acid systems are present, or if alternator and charger outputs have changed, review the complete design and manufacturer requirements. A distribution unit cannot correct an inappropriate charging profile or a battery that is already failing, so bank condition and charger configuration should form part of diagnosis.

Protection and installation layout

Inspect fuses, breakers, isolators and busbars serving both inputs and all outputs. Protection must suit the conductors and connected equipment. Keep the unit accessible for inspection and label the cables so each source and bank can be identified. On a replacement job, photograph and label all connections before removal. This is particularly important with two inputs because confusing the sources can complicate commissioning and future fault finding.

Commissioning and fault finding

Before energising, verify polarity, terminal functions and protective devices. Test each charging source under realistic operating conditions and confirm that the intended banks receive charge. Measure voltage at the sources and battery banks and check high-current joints for abnormal voltage drop or heating. If a bank charges poorly, investigate battery condition, fuses, isolators and cable resistance as well as the RCE. Record the final connection layout and protection for future service.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. Use current Cristec documentation as the final reference for ratings, terminal functions and installation. F&C Marine’s Marine Electronics Knowledge Base also provides practical marine electrical guidance.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec RCE160-2EM6-3SM6-PL

Send F&C Marine the vessel type, system voltage, details of both charging sources, battery-bank voltage and chemistry, cable sizes, fuse information and photographs of the present installation. If this is a replacement, include the old unit’s model and fault symptoms. We can then help confirm the 160A two-input, three-output M6 configuration and current availability.