Cristec SOLO12-230/500-50 – 12V/500VA 50Hz Pure Sine Wave Inverter

£421.00 ex. VAT

Cristec SOLO12-230/500-50 12VDC, 500VA, 230V 50Hz pure sine wave marine inverter. Contact F&C Marine for load and installation matching.

SKU: SOLO12-230/500-50 Categories: , Brand:

Description

Cristec SOLO12-230/500-50 pure sine wave inverter

Cristec SOLO12-230/500-50 is the 12VDC, 500VA, 230V 50Hz pure sine wave inverter configuration listed in the Cristec SOLO range. A marine inverter needs to be matched to the battery bank, connected AC load, DC cable length, protection, mounting and ventilation. Because the output is mains voltage, installation and any connection to the vessel AC distribution should be carried out by a competent person using current Cristec documentation and applicable marine electrical requirements.

Cristec SOLO12-230/500-50

Matching 500VA to the intended load

Identify every item expected to run from the inverter and compare the combined normal load with the 500VA rating. Also consider starting and surge demand. Motors, pumps, refrigeration equipment and some electronic power supplies can draw much more for a short period than their normal running figure suggests. If an existing inverter has been shutting down, establish whether the problem is overload, surge current, low battery voltage or poor cabling before simply fitting a larger replacement.

12V battery-bank planning

The inverter draws energy from the 12V battery system, so battery capacity, chemistry and state of charge determine how well the installation performs. Check the charging sources that replenish the bank, including alternators, shore chargers and solar systems where fitted. A battery that is weak or insufficiently charged can cause low-voltage shutdown even when the AC load is within the inverter rating. Lithium installations also need to stay within the battery-management system’s permitted discharge current.

DC cabling, fusing and isolation

Use DC conductors and protective devices appropriate to the inverter current and cable route. Voltage drop on a 12V system can be significant, so conductor size, route length and connection quality matter. Inspect lugs, fuse holders, isolators and busbars for corrosion, looseness or heat damage before reusing existing wiring. Support cables so they do not strain the inverter terminals and protect positive conductors against accidental short circuit. The current Cristec manual should provide the final cable and protection requirements.

AC output and electrical safety

The SOLO inverter produces mains-voltage AC. Any permanent connection to vessel sockets or an AC distribution system needs suitable protection, isolation and source-changeover arrangements where shore or generator power is also present. Neutral and protective-earth treatment must follow the manufacturer instructions and applicable marine standards. Two AC sources must not be unintentionally connected together. Work on mains circuits should be isolated, verified safe and completed by a competent marine electrician.

Mounting, ventilation and service access

Install the inverter in a dry, protected position that meets Cristec’s environmental and cooling requirements. Leave enough clearance for ventilation and access to terminals, controls and protective devices. Avoid mounting where water, excessive heat or mechanical damage could affect the unit. When replacing older equipment, compare dimensions and cable-entry positions before modifying the mounting surface and confirm that the previous location remains suitable.

Commissioning and fault finding

Commissioning should include checking battery voltage at rest and under load, operation with representative AC equipment and any alarms or shutdown indications. Inspect DC connections for abnormal heating and measure voltage drop if performance is poor. If the inverter trips, determine whether the cause is overload, surge demand, low battery voltage, poor cabling or excessive temperature before assuming the inverter is faulty. Record the installed model, protection and connected loads for future maintenance.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. Use current SOLO documentation as the final reference for ratings, cabling, protection, earthing, mounting and operating limits. F&C Marine also provides a Marine Electronics Knowledge Base for related vessel electrical guidance.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec SOLO12-230/500-50

Send F&C Marine the vessel type, battery voltage, chemistry and capacity, equipment to be powered, existing inverter model if applicable, approximate DC cable length and photographs of the installation. If this is a fault replacement, include any alarms and voltage measurements. We can then help confirm whether the 500VA 12V version is suitable and identify likely installation requirements before quotation.

Reviews