Description
Cristec SOLO24-230/1300-50 pure sine wave inverter
Cristec SOLO24-230/1300-50 is the 24VDC, 1300VA, 230V 50Hz pure sine wave inverter configuration listed in the Cristec SOLO range. Marine inverter selection requires the battery bank, connected AC load, DC cable length, protection, mounting and ventilation to be considered together. Because the output is mains voltage, installation and any permanent connection to vessel AC distribution should be completed by a competent person using current Cristec documentation and applicable marine electrical requirements.

Matching 1300VA to the intended load
Identify the AC equipment expected to operate from the inverter and compare combined normal demand with the 1300VA rating. Starting and surge loads also matter. Motors, pumps, refrigeration equipment and some power supplies can draw significantly more current briefly than their normal rating. Consider which loads may operate simultaneously. If an older inverter has been shutting down, determine whether the cause is overload, low battery voltage, cable voltage drop, overheating or a fault in the connected equipment before replacement.
24V battery-bank requirements
A 1300VA inverter places a meaningful load on a 24V battery bank. Check battery capacity, chemistry, condition and expected operating duration. Review charging sources such as alternators, shore chargers and solar controllers so the bank can recover appropriately. Lithium batteries must stay within BMS discharge limits, while lead-acid batteries should be assessed for voltage sag and usable capacity under load. An inadequate or poorly charged bank can make a correctly sized inverter appear unreliable.
DC cabling, protection and isolation
DC conductors should be sized for current, route length and acceptable voltage drop and protected with suitable overcurrent devices. Inspect existing lugs, fuse holders, isolators and busbars for heat damage, looseness or corrosion. Support heavy conductors so they do not strain terminals and protect positive connections against accidental short circuit. Follow current Cristec cable and protection requirements rather than assuming the wiring used by a smaller or older inverter is suitable.
AC integration and electrical safety
The SOLO output is mains voltage and requires appropriate electrical protection. Permanent integration with vessel sockets or distribution should consider source changeover, isolation, protective earth and neutral arrangements. The exact design depends on the wider AC system and applicable marine electrical standards. Do not permit inverter, shore and generator sources to become unintentionally paralleled. Mains work should be isolated, verified safe and carried out by a competent marine electrician.
Mounting, cooling and commissioning
Mount the inverter in a dry, protected location with the clearances and ventilation specified by Cristec. Keep terminals and protective devices accessible for service. During commissioning, check battery voltage with the inverter idle and under representative load, observe alarms and inspect for abnormal heating. If performance is poor, measure DC voltage drop and check the battery and connections before assuming the inverter is defective. Record the installed model, cable protection and connected circuits.
Documentation and related guidance
For current manufacturer information see Cristec marine electrical products. Current SOLO documentation should be the final reference for ratings, cabling, protection, earthing, mounting and operating limits. F&C Marine also provides a Marine Electronics Knowledge Base for related vessel electrical guidance.
Official manuals, datasheets and brochures
Related products
- Cristec SOLO24-230/350-50 – 24V/350VA 50Hz Pure Sine Wave Inverter
- Cristec SOLO48-230/400-50 – 48V/400VA 50Hz Pure Sine Wave Inverter
- Cristec SOLO12-230/1000-50 – 12V/1000VA 50Hz Pure Sine Wave Inverter
Related technical resources
Before ordering Cristec SOLO24-230/1300-50
Send F&C Marine the vessel type, battery voltage, chemistry and capacity, equipment to be powered, existing inverter details, approximate DC cable length, charging-system information and photographs of the installation. If this is a fault replacement, include alarms and voltage measurements. We can then help confirm whether the 1300VA 24V version is suitable and identify installation requirements before quotation.