Description
Cristec SOLO48-230/400-50 pure sine wave inverter
Cristec SOLO48-230/400-50 is the 48VDC, 400VA, 230V 50Hz pure sine wave inverter configuration listed in the Cristec SOLO range. A marine inverter needs to be matched to the battery bank, connected AC load, DC cable length, protection, mounting and ventilation. Because the output is mains voltage, installation and any connection to vessel AC distribution should be carried out by a competent person using current Cristec documentation and applicable marine electrical requirements.

Matching 400VA to the intended load
Identify the equipment that will run from the inverter and compare the 400VA rating with normal running demand and any short starting or surge requirement. Small electronics can have low continuous consumption, while motors, pumps and some power supplies may draw significantly more at start-up. Avoid selecting the inverter only from the normal wattage printed on one appliance if several devices may be connected or if a load has a substantial starting characteristic.
48V battery-bank planning
The inverter draws from the 48V battery system, so battery capacity, chemistry and state of charge affect operating time and DC voltage stability. Check the condition and capacity of the bank and consider the charging sources that replenish it. A weak or poorly charged bank can cause low-voltage shutdown even when the AC load itself is within the inverter rating. Lithium systems should also be checked against BMS discharge limits and any communication or protective requirements associated with the bank.
DC cabling, fusing and isolation
Use DC conductors and protective devices appropriate to the inverter current and cable route. Cable length, conductor size and connection quality influence voltage drop and reliability. Inspect lugs, fuse holders, isolators and busbars for corrosion, looseness or heat damage before reusing existing wiring. Support cables so they do not strain terminals and protect positive conductors against accidental short circuit. Follow the current Cristec manual for final cable and protection requirements.
AC output and electrical safety
The SOLO inverter produces mains-voltage AC. Any permanent connection to vessel sockets or distribution needs appropriate protection, isolation and source-changeover arrangements where shore or generator power is also present. Neutral and protective-earth treatment must follow manufacturer instructions and applicable marine standards. Do not connect separate AC sources together unintentionally. Work on mains circuits should be isolated, verified safe and completed by a competent marine electrician.
Mounting, ventilation and service access
Install the inverter in a dry, protected position meeting Cristec’s environmental and cooling requirements. Leave sufficient clearance for ventilation and access to terminals, controls and protective devices. Avoid mounting where water, excessive heat or mechanical damage could affect the unit. When replacing older equipment, compare dimensions and cable-entry positions before modifying the mounting surface and verify that the previous location remains suitable.
Commissioning and fault finding
Commissioning should include checking battery voltage at rest and under load, operation with the intended AC equipment and any alarms or shutdown indications. Inspect DC connections for abnormal heating and measure voltage drop if performance is poor. If the inverter trips, determine whether the cause is overload, surge demand, low battery voltage, poor cabling or excessive temperature before assuming the inverter is faulty. Record the installed model, protection and connected loads for future maintenance.
Documentation and related guidance
For current manufacturer information see Cristec marine electrical products. Use current SOLO documentation as the final reference for ratings, cabling, protection, earthing, mounting and operating limits. F&C Marine also provides a Marine Electronics Knowledge Base for related vessel electrical guidance.
Official manuals, datasheets and brochures
Related products
- Cristec SOLO24-230/1300-50 – 24V/1300VA 50Hz Pure Sine Wave Inverter
- Cristec SOLO48-230/700-50 – 48V/700VA 50Hz Pure Sine Wave Inverter
- Cristec SOLO24-230/350-50 – 24V/350VA 50Hz Pure Sine Wave Inverter
Related technical resources
Before ordering Cristec SOLO48-230/400-50
Send F&C Marine the vessel type, battery voltage, chemistry and capacity, equipment to be powered, existing inverter model if applicable, approximate DC cable length and photographs of the installation. If this is a fault replacement, include alarms and voltage measurements. We can then help confirm whether the 400VA 48V version is suitable and identify likely installation requirements before quotation.










Reviews
There are no reviews yet.