Cristec SOLO48-230/700-50 – 48V/700VA 50Hz Pure Sine Wave Inverter

£663.00 ex. VAT

Cristec SOLO48-230/700-50 48VDC, 700VA, 230V 50Hz pure sine wave marine inverter. Contact F&C Marine for load and installation matching.

SKU: SOLO48-230/700-50 Categories: , Brand:

Description

Cristec SOLO48-230/700-50 pure sine wave inverter

Cristec SOLO48-230/700-50 is the 48VDC, 700VA, 230V 50Hz pure sine wave inverter configuration listed in the Cristec SOLO range. Marine inverter selection requires the battery bank, connected AC load, DC cable length, protection, mounting and ventilation to be considered together. Because the output is mains voltage, installation and any permanent connection to vessel AC distribution should be completed by a competent person using current Cristec documentation and applicable marine electrical requirements.

Cristec SOLO48-230/700-50

Matching 700VA to the intended load

Identify the AC equipment expected to operate from the inverter and compare combined normal demand with the 700VA rating. Starting and surge loads also matter. Motors, pumps, refrigeration equipment and some power supplies can draw significantly more current briefly than their normal rating. Consider which loads may operate simultaneously. If an older inverter has been shutting down, determine whether the cause is overload, low battery voltage, cable voltage drop, overheating or a fault in the connected equipment before replacement.

48V battery-bank requirements

Check battery capacity, chemistry, condition and expected operating duration. Review charging sources so the bank can recover appropriately after inverter use. Lithium batteries must remain within BMS discharge limits and any associated control requirements, while other battery technologies should be assessed for condition and voltage stability under load. An inadequate or poorly charged bank can make a correctly sized inverter appear unreliable even when the AC demand is within specification.

DC cabling, protection and isolation

DC conductors should be sized for current, route length and acceptable voltage drop and protected with suitable overcurrent devices. Inspect existing lugs, fuse holders, isolators and busbars for heat damage, looseness or corrosion. Support conductors so they do not strain terminals and protect positive connections against accidental short circuit. Follow current Cristec cable and protection requirements rather than assuming wiring used by another inverter is suitable simply because it reaches the new installation position.

AC integration and electrical safety

The SOLO output is mains voltage and requires appropriate electrical protection. Permanent integration with vessel sockets or distribution should consider source changeover, isolation, protective earth and neutral arrangements. The exact design depends on the wider AC system and applicable marine electrical standards. Do not permit inverter, shore and generator sources to become unintentionally paralleled. Mains work should be isolated, verified safe and carried out by a competent marine electrician.

Mounting, cooling and commissioning

Mount the inverter in a dry, protected location with the clearances and ventilation specified by Cristec. Keep terminals and protective devices accessible for service. During commissioning, check battery voltage with the inverter idle and under representative load, observe alarms and inspect for abnormal heating. If performance is poor, measure DC voltage drop and check the battery and connections before assuming the inverter is defective. Record the installed model, cable protection and connected circuits.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. Current SOLO documentation should be the final reference for ratings, cabling, protection, earthing, mounting and operating limits. F&C Marine also provides a Marine Electronics Knowledge Base for related vessel electrical guidance.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec SOLO48-230/700-50

Send F&C Marine the vessel type, battery voltage, chemistry and capacity, equipment to be powered, existing inverter details, approximate DC cable length, charging-system information and photographs of the installation. If this is a fault replacement, include alarms and voltage measurements. We can then help confirm whether the 700VA 48V version is suitable and identify installation requirements before quotation.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.