Cristec VLTG-70 – Voltage Guard 12V & 24V DC – 70amp capacity

£135.00 ex. VAT

Cristec VLTG-70 12/24V DC voltage guard with 70A capacity for low-voltage load protection. Contact F&C Marine for system matching and installation support.

SKU: VLTG-70 Categories: , Brand:

Description

Cristec VLTG-70 voltage guard

Cristec VLTG-70 is the 12V and 24V DC voltage guard listed with a 70A capacity. Its purpose is to protect a battery against deep discharge by disconnecting a load at a predetermined voltage. Correct use depends on the battery system, load current, cable size, protection and the disconnect/reconnect settings required for the vessel, so the complete DC circuit should be reviewed before installation.

Cristec VLTG-70

Protecting the correct DC load

Start by identifying which load or group of loads needs low-voltage protection and which battery bank supplies it. Essential services and safety-critical equipment may have different requirements from domestic or auxiliary loads, so a voltage guard should not simply be inserted into an unknown circuit. Record the expected continuous current and any higher starting or surge current, then compare the installation with the current Cristec instructions and the vessel’s electrical design before fitting the device.

Battery voltage and disconnect settings

The VLTG-70 is listed for 12V and 24V DC systems, but the appropriate low-voltage threshold depends on the battery installation and intended use. Battery chemistry, normal operating voltage, cable voltage drop and the loads connected to the bank can all affect what the device sees. A threshold that is too high may cause nuisance disconnection, while one that is too low may not provide the intended protection. Use the battery manufacturer’s limits and the current Cristec documentation when deciding how the system should operate.

Cable sizing, fusing and isolation

The protected circuit may carry significant current, so conductors and protective devices must be appropriate for the load and route length. Inspect existing fuses, isolators, busbars, terminals and cable condition when adding the voltage guard. High resistance in a poor connection can create a local voltage drop that causes unexpected operation even when the battery itself is healthy. Support cables mechanically, keep terminals protected from accidental short circuit and route wiring away from water, heat and sharp edges.

Installation position and access

Mount the device in a dry, protected and accessible location that meets the current manufacturer requirements. The installation should allow future inspection of connections and any settings or indicators. If the VLTG-70 is replacing an older protection device, confirm the function of every existing conductor before removal and photograph the original arrangement. Do not assume that an old cable size or fuse is correct simply because it was previously installed.

Commissioning the protection function

Commissioning should verify more than normal-load operation. Confirm supply polarity and voltage, check the protected load current and make sure the device remains stable under normal conditions. The disconnect and reconnect behaviour should be checked in accordance with the manufacturer procedure without exposing connected equipment to unsuitable voltages. If nuisance trips occur, investigate battery condition, charge state, cable voltage drop, high starting current and poor connections before changing settings. Record the final configuration for future service.

Documentation and related guidance

For current manufacturer information see Cristec marine electrical products. The current Cristec instructions should remain the final reference for ratings, settings, wiring and installation. F&C Marine also provides a Marine Electronics Knowledge Base with practical marine electrical guidance.

Official manuals, datasheets and brochures


Related products


Related technical resources

Before ordering Cristec VLTG-70

Send F&C Marine the vessel type, system voltage, battery chemistry and capacity, the load to be protected, expected current, existing fuse and cable information and photographs of the installation. If replacing a faulty unit, include the symptoms and voltage measurements already taken. We can then help confirm whether the VLTG-70 is appropriate and identify any installation changes before quotation.