Description
Koden JB-35 radar junction box
Koden JB-35 is a radar junction box listed complete with a CW-376-5M cable. A junction box forms part of the radar interconnection and should be selected by exact model reference, not only by connector appearance. F&C Marine can help check the intended Koden radar arrangement and confirm whether the JB-35 and supplied cable are appropriate before the part is ordered for a new installation, repair or refit.

Role in the radar installation
Junction boxes are used to organise connections between parts of a marine radar system and can be critical when a cable run is being adapted or equipment is being replaced. The correct unit needs to match the radar family, cable set and connection arrangement. When replacing an existing box, record its model number, cable labels, connected equipment and wire destinations before disturbing the installation. Photographs of the wiring and connector layout can prevent confusion when the replacement is fitted.
Mounting and cable routing
The junction box should be installed where it remains protected and accessible for inspection or future service. Cable entries need to be routed so conductors and connectors are not strained, sharply bent or exposed to water. Existing cable trays and penetrations can often be reused if they remain suitable, but damaged glands, unsupported cable or corrosion around terminations should be corrected as part of the work. The supplied CW-376-5M cable should be routed in accordance with the relevant Koden installation documentation.
Fault finding around junction boxes
Intermittent radar faults can be caused by poor connections, corrosion, damaged cable, moisture or earlier alterations in a junction point. Before replacing the box, inspect all terminations and look for evidence of heat, contamination, loose hardware or water ingress. A fault that appears when the vessel vibrates or when a cable is moved can point towards an interconnection issue. The wider radar power and data installation should also be considered so a good junction box is not replaced when the actual fault is elsewhere.
Commissioning after replacement
After fitting, verify each connection against the applicable diagram before energising the equipment. Confirm radar power, scanner operation and all navigation or control data that passes through the arrangement. Secure the cables and check that equipment can be serviced without pulling on the terminations. If the work is part of a complete radar replacement, include the junction box in the overall commissioning record so the fitted part number and cable configuration are available for future maintenance.
Documentation and related guidance
For current Koden information, see Koden marine electronics. The relevant installation manual is the final reference for connection assignments, cable use and mounting requirements. You can also browse F&C Marine radar parts, our marine radar systems and the Marine Electronics Knowledge Base for related technical information.
Official manuals, datasheets and brochures
Related products
- Koden CW-401-10M – Keyboard cable 10M for MRO-108/110
- Koden CW-401-5M – Keyboard cable 5M for MRO-108/110
- Koden MDC-7025PS – with 6ft open scanner (RW701A-06)
Related technical resources
- Marine radar blind sectors explained
- Marine Radar vs AIS – why vessels need both
- Marine radar interference explained
- Solid-state vs magnetron marine radar
Before ordering Koden JB-35
Send F&C Marine the radar model, existing junction-box reference, photographs of the current connections and details of the cable route. If the part is required for a fault, include the symptoms and any tests already carried out. We can then help confirm compatibility, availability and whether any additional cable or installation parts are likely to be required. Correct identification before ordering is particularly important where several related Koden radar systems use visually similar interconnection hardware.